2.13.9 Pneumatic operated shut off 3/2 valves
Theactuatingpressurehastobesuppliedwitha3/2wayvalve.
Whenthevalveisnotactuatedtheairactuationinputhastovent.
Actuationpressure:
Minimal :4 bar(g).
Maximal :9 bar(g).
- Removing
Ensurethatthesystemisdepressurisedbeforetakingthe
pneumatic3/2valveapart.
Removetheactuatingpressuretubingloosenthe4boltswith
hexagonheadcounterclockwisetoreleasethevalve.
- Replacing
ReplacethegasketAS007andAS017,Viton,EPDM
orKalrez.
Allwettedpartshavetobeabsolutelyclean,don’tuseoilor
greaseandavoiddust!
Replacethepneumatic3/2valveandtightenthebolts
withhexagonheadbyturningclockwise,tightencrosswise
withM30,9Nm.
Replacetheactuatingpressuretubing.
Nowthepneumatic3/2valvehastobetestedforleakage
andfunction.
9.17.057 page 15
AvailablePneumaticoperated3/2valves
Modelnumber Description
PV32V NC:Kv=0,2/NO:Kv=0.085
3/2wayValvewithVitonseals
PV32E NC:Kv=0,2/NO:Kv=0.085 3/2wayValvewithEPDMseals
PV32K NC:Kv=0,2/NO:Kv=0.085 3/2wayValvewithKalrezseals
2.13.10 Filter modules
- Removal
Ensurethatthesystemisdepressurisedbeforetakingfilterapart.
Removethefiltercup/cartrigeassybyloosenthe4boltswith
hexagonheadcounterclockwisetoreleasetheassy.
Fordisassemblingthefilteruseaneedlenosepliersplaceit
inthebottompartandturnthepartcounterclockwisefor
releasethefilter.
- Replacement
ReplacethegasketsAS007,AS017andwhennecessary
AS012,Viton,EPDMorKalrez.
Whennecessaryreplacethefiltercup/cartridge.Thesecan
beorderedseparately,becauseadirtyfilterwillcause 
extrapressurelossoverthesystem.
Allwettedpartshavetobeabsolutelyclean,don’tuseoil
orgreaseandavoiddust!
ReplacethefilterandwhennecessarytheAS012gasket.
Tightenthebottomparthandtightintothecover.
Placethegasketsandtightentheboltswithhexagonhead
byturningclockwise,tightencrosswisewithM30,9Nm.
Now the filter has to be tested for leakage and function.
AvailableFiltermodules
Modelnumber Description
 ElementPoreSize[μm]
FF01 0,5
FF02 2
FF03 7
FF04 15